{"product_id":"implant-and-screw-removal-kit","title":"Implant and Screw Removal Kit","description":"\u003cp\u003eThe Implant and Screw Removal Kit is designed for the removal of failed implants, stripped screws, and fractured screws. Three sizes of fixture removers ensure compatibility with virtually any implant size. The fixture removers cross-thread with the implant's internal threads, securely fusing the two pieces together for efficient removal. A variety of screw removal instruments are included to help clinicians remove both fractured and stripped prosthetic screws. This comprehensive kit provides everything needed to remove implants and screws, making it an essential addition to any implant practice.\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"899\" data-start=\"872\" data-section-id=\"wcz4o7\"\u003eScrew Removal Components\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"1058\" data-start=\"901\"\u003e\n\u003cli data-end=\"926\" data-start=\"901\" data-section-id=\"kuuhir\"\u003eProsthetic Guide Holder\u003c\/li\u003e\n\u003cli data-end=\"948\" data-start=\"927\" data-section-id=\"l1cmqi\"\u003eLong Ratchet Wrench\u003c\/li\u003e\n\u003cli data-end=\"988\" data-start=\"949\" data-section-id=\"1em3otw\"\u003eAdapter (Contra Angle to 4 mm Square)\u003c\/li\u003e\n\u003cli data-end=\"1005\" data-start=\"989\" data-section-id=\"miswys\"\u003eReverse Drills\u003c\/li\u003e\n\u003cli data-end=\"1020\" data-start=\"1006\" data-section-id=\"1p59uvy\"\u003eReverse Taps\u003c\/li\u003e\n\u003cli data-end=\"1038\" data-start=\"1021\" data-section-id=\"1dvt2xw\"\u003eFlat Tip Driver\u003c\/li\u003e\n\u003cli data-end=\"1058\" data-start=\"1039\" data-section-id=\"i6quew\"\u003eProsthetic Guides\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"1098\" data-start=\"1065\" data-section-id=\"7xlfag\"\u003eProsthetic Guide Compatibility\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ch3 data-end=\"1121\" data-start=\"1100\" data-section-id=\"10zvt6c\"\u003eExternal Mini (M)\u003c\/h3\u003e\n\u003cul data-end=\"1176\" data-start=\"1123\"\u003e\n\u003cli data-end=\"1139\" data-start=\"1123\" data-section-id=\"16fm9j7\"\u003eHi-Tec Summit®\u003c\/li\u003e\n\u003cli data-end=\"1176\" data-start=\"1140\" data-section-id=\"xtddnt\"\u003eNobel Biocare Branemark System NP®\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1199\" data-start=\"1178\" data-section-id=\"go77a\"\u003eOcta Internal (O)\u003c\/h3\u003e\n\u003cul data-end=\"1297\" data-start=\"1201\"\u003e\n\u003cli data-end=\"1238\" data-start=\"1201\" data-section-id=\"1tlqya5\"\u003eHi-Tec Tite-Fit \u0026amp; Tapered Tite-Fit®\u003c\/li\u003e\n\u003cli data-end=\"1268\" data-start=\"1239\" data-section-id=\"1uqgc84\"\u003eStraumann ITI Tissue Level®\u003c\/li\u003e\n\u003cli data-end=\"1297\" data-start=\"1269\" data-section-id=\"tsy4hl\"\u003eImplant Direct SwishPlant®\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1316\" data-start=\"1299\" data-section-id=\"11qmdo9\"\u003eTSV 3.7 \/ 4.1\u003c\/h3\u003e\n\u003cul data-end=\"1508\" data-start=\"1318\"\u003e\n\u003cli data-end=\"1354\" data-start=\"1318\" data-section-id=\"1x69yih\"\u003eHi-Tec Logic+, Spark, Self-Thread®\u003c\/li\u003e\n\u003cli data-end=\"1398\" data-start=\"1355\" data-section-id=\"1mfgs1a\"\u003eBioHorizons Tapered Internal 3.7 and 4.7®\u003c\/li\u003e\n\u003cli data-end=\"1450\" data-start=\"1399\" data-section-id=\"m1it2a\"\u003eImplant Direct Legacy® (3.7 and 4.7 Internal Hex)\u003c\/li\u003e\n\u003cli data-end=\"1476\" data-start=\"1451\" data-section-id=\"1upsxb7\"\u003eMIS 3.3, 3.75, and 4.2®\u003c\/li\u003e\n\u003cli data-end=\"1508\" data-start=\"1477\" data-section-id=\"w3ktqs\"\u003eZimmer TSV 3.7, 4.1, and 4.7®\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1534\" data-start=\"1510\" data-section-id=\"9xoauv\"\u003eExternal Regular (W)\u003c\/h3\u003e\n\u003cul data-end=\"1572\" data-start=\"1536\"\u003e\n\u003cli data-end=\"1572\" data-start=\"1536\" data-section-id=\"xtd4dx\"\u003eNobel Biocare Branemark System RP®\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1595\" data-start=\"1574\" data-section-id=\"1dwe3wi\"\u003eHex Submerged (H)\u003c\/h3\u003e\n\u003cul data-end=\"1660\" data-start=\"1597\"\u003e\n\u003cli data-end=\"1631\" data-start=\"1597\" data-section-id=\"q2pfun\"\u003eHi-Tec Logic, Implex, Expert® NL\u003c\/li\u003e\n\u003cli data-end=\"1660\" data-start=\"1632\" data-section-id=\"1e0atbv\"\u003eNobel Biocare NobelActive®\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1680\" data-start=\"1662\" data-section-id=\"1dcrpjv\"\u003eTrilobe 3.5 NP\u003c\/h3\u003e\n\u003cul data-end=\"1732\" data-start=\"1682\"\u003e\n\u003cli data-end=\"1702\" data-start=\"1682\" data-section-id=\"1m8ib10\"\u003eHi-Tec Vision® 3.5\u003c\/li\u003e\n\u003cli data-end=\"1732\" data-start=\"1703\" data-section-id=\"og7afy\"\u003eNobel Biocare Tri Lobe® 3.5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"1781\" data-start=\"1739\" data-section-id=\"1v4kpfa\"\u003eInstructions for Stripped Screw Removal\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-end=\"2040\" data-start=\"1783\"\u003eStripped screws are generally more difficult to remove than fractured screws because fractured screws are not under compression. The most effective method is to create a flathead channel with a round bur, then use a flat tip driver to reverse the screw out.\u003c\/p\u003e\n\u003ch3 data-end=\"2052\" data-start=\"2042\" data-section-id=\"onaaw5\"\u003eStep 1\u003c\/h3\u003e\n\u003cp data-end=\"2182\" data-start=\"2054\"\u003eUsing a 1\/2 round bur in a high-speed handpiece, create a channel across the diameter of the screw head to form a flathead slot.\u003c\/p\u003e\n\u003cp data-end=\"2212\" data-start=\"2184\"\u003e\u003cstrong data-end=\"2212\" data-start=\"2184\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0266\/2160\/7995\/files\/1_b6970304-7c4b-487f-bc12-34fca300bff1.jpg?v=1784280874\" alt=\"\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"2224\" data-start=\"2214\" data-section-id=\"onaaw6\"\u003eStep 2\u003c\/h3\u003e\n\u003cp data-end=\"2316\" data-start=\"2226\"\u003eAfter the channel is created, use the FTD-01 and the ratchet wrench to back the screw out.\u003c\/p\u003e\n\u003cp data-end=\"2346\" data-start=\"2318\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0266\/2160\/7995\/files\/2_91eb2a32-8106-4d2e-8288-5ce2890c64e5.jpg?v=1784280964\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"2396\" data-start=\"2353\" data-section-id=\"1k5kndb\"\u003eInstructions for Fractured Screw Removal\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ch3 data-end=\"2408\" data-start=\"2398\" data-section-id=\"onaaw5\"\u003eStep 1\u003c\/h3\u003e\n\u003cp data-end=\"2551\" data-start=\"2410\"\u003ePress the remover drill (D-REM) in reverse (under 80 RPM) against the fractured screw to reverse the screw fragment out of the screw channel.\u003c\/p\u003e\n\u003cp data-end=\"2581\" data-start=\"2553\"\u003e\u003cstrong data-end=\"2581\" data-start=\"2553\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0266\/2160\/7995\/files\/2_91eb2a32-8106-4d2e-8288-5ce2890c64e5.jpg?v=1784280964\" alt=\"\"\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"2593\" data-start=\"2583\" data-section-id=\"onaaw6\"\u003eStep 2\u003c\/h3\u003e\n\u003cp data-end=\"2728\" data-start=\"2595\"\u003eIf the remover drill is unsuccessful, use the guide information to select the correct prosthetic guide based on the implant platform.\u003c\/p\u003e\n\u003ch3 data-end=\"2740\" data-start=\"2730\" data-section-id=\"onaaw7\"\u003eStep 3\u003c\/h3\u003e\n\u003cp data-end=\"2833\" data-start=\"2742\"\u003eAttach the selected guide to the guide handle and engage the connection within the implant.\u003c\/p\u003e\n\u003ch3 data-end=\"2845\" data-start=\"2835\" data-section-id=\"onaaw0\"\u003eStep 4\u003c\/h3\u003e\n\u003cp data-end=\"2951\" data-start=\"2847\"\u003eWith the handpiece in reverse (1,200–1,300 RPM), create a divot in the top of the screw using the D-REM.\u003c\/p\u003e\n\u003ch3 data-end=\"2963\" data-start=\"2953\" data-section-id=\"onaaw1\"\u003eStep 5\u003c\/h3\u003e\n\u003cp data-end=\"2993\" data-start=\"2965\"\u003eRemove the prosthetic guide.\u003c\/p\u003e\n\u003ch3 data-end=\"3005\" data-start=\"2995\" data-section-id=\"onaaw2\"\u003eStep 6\u003c\/h3\u003e\n\u003cp data-end=\"3117\" data-start=\"3007\"\u003eWith the handpiece in reverse (under 80 RPM), press the tap into the screw channel until it engages the screw.\u003c\/p\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"3192\" data-start=\"3163\" data-section-id=\"1tqozlg\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0266\/2160\/7995\/files\/3_a4a45d8e-7284-4dfe-a6c9-2e0fc472fae8.jpg?v=1784280966\" alt=\"\"\u003e\u003c\/h2\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"3192\" data-start=\"3163\" data-section-id=\"1tqozlg\"\u003eImplant Removal Components\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"3310\" data-start=\"3194\"\u003e\n\u003cli data-end=\"3234\" data-start=\"3194\" data-section-id=\"1yol6eh\"\u003eFixture Removers (Mini, Regular, Wide)\u003c\/li\u003e\n\u003cli data-end=\"3251\" data-start=\"3235\" data-section-id=\"12u6min\"\u003eTurning Handle\u003c\/li\u003e\n\u003cli data-end=\"3268\" data-start=\"3252\" data-section-id=\"9nuqz4\"\u003eRatchet Wrench\u003c\/li\u003e\n\u003cli data-end=\"3288\" data-start=\"3269\" data-section-id=\"1sigglo\"\u003eRatchet Extension\u003c\/li\u003e\n\u003cli data-end=\"3310\" data-start=\"3289\" data-section-id=\"1ip3prs\"\u003eHandpiece Condenser\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"3360\" data-start=\"3317\" data-section-id=\"1qzj5q1\"\u003eInstructions for Implant Fixture Removal\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-end=\"3623\" data-start=\"3362\"\u003eThis kit uses a series of fixture removers to remove failed implants with minimal bone loss. Attach the appropriate fixture remover to the ratchet wrench, apply downward pressure, and rotate the fixture remover counterclockwise to fuse it to the failed implant.\u003c\/p\u003e\n\u003ch3 data-end=\"3654\" data-start=\"3625\" data-section-id=\"1guu08j\"\u003eFixture Remover Selection\u003c\/h3\u003e\n\u003cp data-end=\"3680\" data-start=\"3656\"\u003e\u003cstrong data-end=\"3680\" data-start=\"3656\"\u003eMini Fixture Remover\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"3734\" data-start=\"3681\"\u003e\n\u003cli data-end=\"3734\" data-start=\"3681\" data-section-id=\"1qy0j5e\"\u003eFor reduced diameter implants (smaller than 3.5 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"3763\" data-start=\"3736\"\u003e\u003cstrong data-end=\"3763\" data-start=\"3736\"\u003eRegular Fixture Remover\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"3809\" data-start=\"3764\"\u003e\n\u003cli data-end=\"3809\" data-start=\"3764\" data-section-id=\"14lrc1e\"\u003eFor standard platform implants (3.5–4.5 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"3835\" data-start=\"3811\"\u003e\u003cstrong data-end=\"3835\" data-start=\"3811\"\u003eWide Fixture Remover\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"3885\" data-start=\"3836\"\u003e\n\u003cli data-end=\"3885\" data-start=\"3836\" data-section-id=\"e5xwxd\"\u003eFor wide platform implants (larger than 4.5 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"3989\" data-start=\"3887\"\u003e\u003cstrong data-end=\"3896\" data-start=\"3887\"\u003eNote:\u003c\/strong\u003e Always ensure the fixture remover fits tightly within the implant connection before removal.\u003c\/p\u003e\n\u003cp data-end=\"4029\" data-start=\"3991\"\u003e\u003cstrong data-end=\"4029\" data-start=\"3991\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0266\/2160\/7995\/files\/4_b701d2f1-69cf-4080-bfd4-25cb4254e90a.jpg?v=1784280927\" alt=\"\"\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Surgident","offers":[{"title":"Default Title","offer_id":43941587386593,"sku":"SD-FSR","price":679.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0266\/2160\/7995\/products\/sd-fsr_2_95660cc0-f73a-4ca0-a5f1-1963209f285a.jpg?v=1689626352","url":"https:\/\/www.avtecdental.com\/en-gb\/products\/implant-and-screw-removal-kit","provider":"Avtec Dental","version":"1.0","type":"link"}